Service difficulty report · Receptacle · Dhav DHC8*

Difficulty date
December 6, 2000
Submitted
January 2, 2001
Operation
General aviation
Make and model
Dhav DHC8*
Part
Receptacle
Part number
MS35061
Condition
Burned
Location
Nr 1 Engine
Component
Dc Power/Distri
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON DEC 6/2000 AFTER ENGINE START ENG NR 1 SMOKE REPORTED COMING FROM DC EXT POWER RECEPTACLE, ENG SHUT DOWN AND POWER RECEPTACLE INSPECTED. FOUND SIGNS OF OVERHEAT WITH MELTED PLASTIC AROUND RECEPTACLE AND SMELL OF BURNED PLASTIC/RUBBER IN NOSE COMPARTMENT. A/C GROUNDED FOR FURTHER INSPECTION. A/C THEN FERRIED TO MAIN BASE FOR FURTHER INSPECTION. FOUND POSITIVE PIN ON RECEPTACLE, BURNT NUT SECURING WIRING LUG TO THE POSITIVE TERMINAL WAS ONLY FINGER TIGHT, PLUS HARDWARE WAS PLAIN NUT AND PLAIN WASHER. RECEPTACLE WAS REPLACED UTILIZING LOCK NUTS. A/C RETURNED TO SERVICE.