What was found
(CAN) DURING SCHEDULED INSPECTION, BOTH FORWARD AND AFT DE-ICE PRESSURE REGULATORS IN THE NR 2 NACELLE FAILED THE FUNCTION TEST PRESCRIBED IN MAINTENANCE TASK 3010/04. BOTH REGULATORS WERE REPLACED AND THE AIRCRAFT WAS RETURNED TO SERVICE. S/N RF3346 6058 CYC 4146 HRS SINCE REPAIR, 24,805 CYC AND 16,732 HRS SINCE NEWS/N RF2705 32,088 CYC 21,780 HRS SINCE NEW.