What was found
(CAN) THE FLIGHT AND GROUND CREW REPORTED THAT THE AIRSTAIR DOOR WOULD NOT CLOSE. IT WOULD NOT ENGAGE ON TO THE DOOR STOPS. MAINTENANCE INVESTIGATION REVEALED THAT THE CLAMP INSTALLED WHEN INCORPORATING MODSUM 8Q101086, SB (8052-56 REV C), HAD SLIPPED OFF THE RAIL TO WHICH IT WAS SECURED. THIS MOD IS PART OF THE REQUIREMENT FOR AIRWORTHINESS DIRECTIVE CF-2000-19R1. THE CLAMP HAD FALLEN TO THE BOTTOM OF THE GAS STRUTS AND INTERFERED WITH THE OPERATION OF THE DOOR CLOSING MECHANISM. THE BRACKET WAS REMOVED AND THE AIRCRAFT DEMODED. PLANNED ACTION IS TO INCORPORATE MODSUM 8Q101074, (SB 8-52-59, REPLACEMENT OF GAS SPRINGS), WHEN THE NEW STYLE SPRINGS BECOME AVAILABLE.