What was found
(CAN) WIRE W200-453-06 CHAFED THROUGH INSULATION AND WIRE. LENGTH & WIDTH OF CHAFE IS 3/8 INCH, DEPTH 1/8 INCH. APPEARS TO HAVE RUBBED AGAINST COWLING AT SOME TIME. HOWEVER, AT TIME OF DISCOVERY, IT WAS NOT APPARENT WHAT THE WIRE HAD CHAFED. THERE HAD BEEN NO REPORTED ELECTRICAL POWER DEFECT. THE HARNESS HAS BEEN REPLACED WITH PARTICULAR EMPHASIS TO CORRECT ROUTING AND CLAMPING.