Service difficulty report · Circuit Breaker · Stbros SD360

Difficulty date
April 7, 2001
Submitted
May 11, 2001
Operation
Air carrier
Make and model
Stbros SD360
Aircraft time
19,141 hours
Engine
Pwa PT6A65AR
Part
Circuit Breaker
Part number
SM600BA100N1
Condition
Shorted
Location
Lt Engine
Stage of operation
CR
How discovered
O
Nature of condition
B, M, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LT ENGINE INLET HEAT OVER HEATED AND RESULTED IN DAMAGING THE INLET HEAT ASSY. THE CAUSE WAS THE REMOTE CIRCUIT BREAKER FAILURE.PILOT REPORTED LEFT INTAKE WILL NOT SHUT OFF. ON GROUND, THE INLET HEATER WAS SMOKING AND CAUSED SMOKE SMELL IN CABIN WITH LEFT BLEED ON. CIRCUIT BREAKERS; 11A + 23 PULLED BUT STILL UNABLE TO SHUT OFF. THE REMOTE BREAKER & INTAKE HEAT GETS ITS POWER DIRECTLY FROM THE LT MAIN BUSBAR. DE-ENERGIZING THE MAIN BUSBAR, IS THE ONLY WAY TO STOP POWER GOING TO THE INTAKE HEAT IF THE REMOTE BREAKER FAILS. IT IS DIFFICULT TO TELL IF THE INTAKE HEAT HAS BEEN TURNED OFF WHILE FLYING.