Service difficulty report · Sleeve · Boeing 747475

Difficulty date
July 17, 2001
Submitted
September 17, 2001
Operation
General aviation
Make and model
Boeing 747475
Aircraft time
44,669 hours, 5,772 cycles
Engine
Ge CF680C2B6F
System (JASC)
2540 · Lavatories
Part
Sleeve
Part number
214861
Condition
Shorted
Location
Dump Valve
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) A/C 381 M FOUND DURING UNRELATED ROUTINE MAINT IN AREA. EVIDENCE OF FIRE DAMAGE CAUSED BY SHORTED LEAD AT WASTER TANK DUMP VALVE HEATER SLEEVE. FIRE TRACK WAS FOLLOWED FROM SOURCE FWD THROUGH LIGHTNING HOLE OF ADJACENT STRUCTURE, & UPWARD ALONG FRAME TO STRINGER 3 FEET FROM AFT DUMP VALVE LOCATION. INSP OF STRUCTURE CARRIED OUT, NIL DEFECTS TO STRUCTURE FOUND. INSULATION BLANKETS REMVD & REPLD DUE TO BURN DAMAGE OF OUTER LAYER. AREA CLEANED OF DUST. AREA RPTECTED. A/C RELEASED FOR SERVICE. BOEING FIELD REP INFORMED. AIR CANADA ENGINEERING TO INVESTIGATE & LIASE WITH BOEING CUSTOMER REPS FOR SOLUTION & FURTHER INSP REQMTS. FLEET CAMPAIGN TO INSPECT AFFECTED AREA IS UNDER CONSIDERATION.