What was found
(CAN) DURING COMPLETION OF ASB 601R-53-61-059 FOUND UPPER WEB OF ENGINE SUPPORT BEAM CRACKED NEAR L & RBL 9.0 AT FS 640. ALSO FOUND HOLES IN SUPPORT ANGLE CRACKED AT RBL 7.5 AND 8.5 (FOUND BY NDT). ALSO FOUND 1/2 INCH CRACK IN LOWER WEB NEAR RBL 36.20 IN THE FWD INBOARD COARNER OF THE ACCESS PANEL LANDING. LHS AT LBL 36.20 PREVIOUSLY REPAIRED IAW REO 601R-53-61-327.REPAIRED IAW REO 601R-53-61-345 (UPPER AN LOWER WEBS) AND REO 601R-53-61-428. INSTALLED REO 601R-53-61-366 (BOTH SIDES).