What was found
(CAN) WIRES WERE DISCOVERED WITH BROKEN AND / OR MISSING OUTER INSULATOR, LEAVING CORE WIRE EXPOSED. THIS DEFECT IS LOCATED IN BEND RADIUS OF WIRING WHEN ADG IS STOWED. THIS WIRING BEING BENT IS NEAR ADG CONNECTOR PIXC, POSSIBLY CHAFING, DETERIORATED ON BACKSHELL IN ADG BAY RT NOSE PANEL 112AR. INSULATION WERE FOUND VERY BRITTLE.DEFECT WERE OF 3/4 INCH TO 1 INCH IN LENGTH (EXPOSED CORE) LOCATED 1/4 INCH AFT OF CONNECTOR ON ADG, BRITTLE ON INSULATION WAS APPROXIMATELY 2.5 INCH IN LENGTH.