What was found
(CAN) DURING 100 HOUR INSPECTION, BOTH AFT BUNGEES WERE FOUND TO BE DISCONNECTED AT THE AFT PUSH PULL TUBE C121-9 AT THE C317-1 BELLCRANK.SUSPECT DISCONNECTION IS DUE TO COLD OPERATING ENVIRONMENT AT THIS TIME. LOCAL TEMPERATURES REACHED BELOW -25 DEGREES C. BUNGEE MATERIAL MAY STIFFEN WHEN COLD CAUSING A LOSS OF ELASTICITY AND ALLOWING FOR DISCONNECTION.NOTE THIS AIRCRAFT HAS THE UPDATED STYLE BUNGEE ATTACHMENT CLIP.