As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(CAN) NR 1 GENERATOR SHUT DOWN IN FLIGHT. AFTER LANDING THE ENGINE WAS SHUTDOWN AND TRIED TO RE-START. STARTER WOULD NOT ENGAGE.INSPECTED LT STARTER GENERATOR, FOUND THAT THE COOLING FAN WHICH IS PART OF UNIT HAD ITS BLADES ALL CRACKED UP. SUSPECTED BEARING FAILURE. REPLACED STARTER GENERATOR, ENGINE RUNS CARRIED OUT AND CHECKED SERVICEABLE.