Service difficulty report · Connector · Braero HS7482A

Difficulty date
June 10, 2002
Submitted
June 13, 2002
Operation
Air carrier
Make and model
Braero HS7482A
Aircraft time
34,539 hours
Engine
Rroyce DART5342
Part
Connector
Condition
Contaminated
Location
Fire Loop
Component
Fire Loop · Graviner
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
B, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DEPARING YYH FOR YCB NR 2 ENGINE FIRE WARNING OBSERVED. DRILL CARRIED OUT AIRCRAFT RETURNED TO POINT OF DEPARTURE LANDING WITH OUT INCIDENT. MAINTENANCE FOUND FIRE LOOP CONNECTOR OIL FOULED, NO EIDENCE OF FIRE, CONNECTOR CLEANED, SYSTEM CHECKED SERVICEABLE. BOTH NR 2 BOTTLES REPLACED AIRCRAFT RETURNED TO SERVICE.