What was found
(CAN) IN CLIMB, EPR 1.515, ENG NR 2 , VIBRATION CONFIRMED ON BOTH CHANNELS, 4.2 INDICATED, CAUSED IN-FLT SHUTDOWN. -ALL MCD INSP & NO CONTAMINATION FOUND PER AMM 72-01-00- VISUAL INSP OF AIR INTAKE , LP COMPRESSOR & EXHAUST COLLECTOR C/OUT & NO FOD OR DEBRIS FOUND. PRESSURE & SCAVENGE FILTERS INSP & REPL PER AMM 72-01-00 (NO CONTAMINATION FOUND).- BOROSCOPE INSP C/OUT PER AMM 72-00-00 ON APPLICABLE STAGES THAT FAULT ISOLATION PROC CALLED FOR IN AMM 71-91-00; INTERMEDIATE PRESSURE COMPRESSOR STAGE 7 L/E , HPC STG 6 L/E, HPT L/E & T/E ; IPT L/E & T/E; NO DAMAGE FOUND ON STAGES MENTIONNED ABOVE. -LP FAN BLADES REMOVED , CLEANED & LUBRICATED & REINST IAW AMM 72-31-02, 72-31-05.