What was found
(CAN) INPUTS HAVE SIGNS OF METAL TRANSFER IN FROM THE ROLLERS TO THE GEAR HOUSING BORE, ON THE RT HOUSING THE ROLLER PATH IS BREAKING UP. OIL-LITE WASHERS ARE WORN, DEBRIS WAS IN OIL FOUND IN AND AROUND THE ROLLER AREA. LT INPUT THE UPPER OIL-LIGHT WAS REMOVED BROKEN. OTHER CRACKS WERE FOUND IN THAT OIL-LIGHT WASHER. LT INPUT FREEWHEEL UNIT SLIPPED DURING FLIGHT. CAUSE OF SLIP IS PRESENTLY UNDER INVESTIGATION.