Service difficulty report · Wire · Cndair CL6002B19

Difficulty date
January 16, 2003
Submitted
February 10, 2003
Operation
Air carrier
Make and model
Cndair CL6002B19
Engine
Ge CF343B1
Part
Wire
Condition
Loose
Location
Terminal Block
Stage of operation
CL
How discovered
O
Nature of condition
H, J
Precautionary procedure
A, D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING CLIMB, FLIGHT CREW RECEIVED EICAS MESSAGES THAT FOLLOW "LT WINDOW HEAT, LT STATIC HEAT, LT AOA HEAT, STBY PITOT HEAT, BASE PITOT HEAT" SINCE ICING CONDITION EXISTED AHEAD, IT WAS DECIDED TO RETURN TO DEPARTURE BASE IT WAS FOUND THAT TWO WIRES, XD14H10B AND XD14J10B, ON TERMINAL BLOCK ITEM NR 75 (TB1-3) WERE LOOSE, AND CAUSED THE WIRES NOT TO SUPPLY POWER TO THE CIRCUIT BREAKERS CBP3 B1 THRU B13. NUTWAS REMOVED BY USING FINGERS ONLY. COMPONENTS REPLACED: 75 - TERMINAL BLOCK - MS27212-2-5 95 -BUSBAR - S1448-4-24-2 100 - WASHER - NAS1149D0363J105 - NUT - MS21042L3 BOTH WIRES GOING FROM TB1 TO CIRCUIT BREAKERS B1 AND B13 ( 6 TO 8 INCHES LONG)