Service difficulty report · Check Valve · Cndair CL600*

Difficulty date
February 18, 2003
Submitted
March 25, 2003
Operation
Air carrier
Make and model
Cndair CL600*
Engine
Lyc ALF502L2C
Part
Check Valve
Part number
ACA3581D71
Condition
Inadequate
Location
Hyd System
Stage of operation
IN
How discovered
9
Nature of condition
N
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) NR 2 HYDRAULIC MANIFOLD EDP (ENGINE DRIVEN PUMP) CHECK VALVE BACKS OUT, O-RING AND BACKUP RING SHEAR ALLOWING PRESSURE INTO THE EDP PRESSURE SWITCH WHEN THE ELECTRIC PUMP IS ON AND ENGINE IS SHUT DOWN. RECURRING DEFECT DUE TO IMPROPER LOCKING DEVICE ON THE CHECK VALVE. MFG FIELD SERVICE REP. NOTIFIED. NO ACTION TAKEN BY MANUFATURER.