Service difficulty report · Trim Panel · Cndair CL6002B19

Difficulty date
March 15, 2003
Submitted
April 14, 2003
Operation
Air carrier
Make and model
Cndair CL6002B19
Engine
Ge CF343B1
Part
Trim Panel
Part number
601R512263
Condition
Failed
Location
Aileron
Part time
21,409 hours
Stage of operation
CL
How discovered
O
Nature of condition
F
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) 6 TO 7 MINUTES AFTER TAKE OFF RUDDER STARTED MOVING FULL RIGHT, RUDDER TRIM. APPLIED LT TRIM - STOPPED AT 1.25 RT DEFLECTION. RUDDER TRIM STUCK. EMERGENCY DECLARED AND DIVERTED TO TPA. R&R'D AILERON TRIM PANEL