What was found
(CAN) LT & RT ELEVATOR TRIM HORN INNER BUSHINGS HAD TO BE DRIVEN OUT OF INNER BUSHINGS WITH HAMMER AND PUNCH. ONCE REMOVED & MEASURED, INNER BUSHING DIMENSION WAS FOUND TO BE THE SAME AS OUTER BUSHING INNER DIAMETER. THERE WAS NO CORROSION BETWEEN THE 2 BUSHINGS. THIS LEFT A 0 CLEARANCE FIT NOT ALLOWING FREE BEARING MOVEMENT. NEW OUTER & INNER BUSHINGS WERE RECEIVED. NEW OUTER BUSHINGS HAVE A MEASURED INNER DIAMETER .3735. REMOVED OUTER BUSHING. ID WAS MEASURED AT .3750. BUSHINGS HAVE BEEN INSTALLED IN ELEVATOR TRIM HORN & INNER BUSHING NOW FREELY ROTATE WITHIN OUTER BUSHING. LT BUSHING LOCATED IN END OF THE ELEVATOR TRIM TAB ACTUATOR ALSO REQUIRED FORCEFUL REMOVAL DUE TO CORROSION. RT SLID OUT FREELY.