What was found
(CAN) THE AIRCRAFT WAS ON A 1ST PHASE 200 HOUR INSPECTION DURING WHICH A VISUAL AND OPERATIONAL CHECK OF THE FLAPS WAS MADE. AT THIS TIME IT WAS NOTICE THAT THE FLAPS DID NOT OPERATE SMOOTHLY. A CLOSER LOOK AND REMOVAL OF THE FLAPS REVEALED THAT BUSHINGS PN 50-160020 WAS SEIZED IN BOTH INBOARD AND OUTBOARD FLAPS BOTH SIDES. THE FLAPS WERE VERY DIFFICULT TO REMOVE AS ALL THE HARDWARE WAS SEIZED IN THE BUSHINGS.