Service difficulty report · Connector · Swrngn SA226TC

Difficulty date
August 24, 2003
Submitted
October 15, 2003
Operation
General aviation
Make and model
Swrngn SA226TC
Aircraft time
26,903 hours
Part
Connector
Part number
PT02E82P
Condition
Burned
Location
Rt Boost Pump
Stage of operation
DE
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) PILOT'S SELECTED RT MAIN BOOST PUMP ON AND CIRCUIT BREAKER POPPED. CIRCUIT BREAKER POPPED AGAIN AND WAS LEFT ALONE FOR REMAINDER OF FLIGHT. THE BOOST PUMP WAS REMOVED AND FOUND THAT THE CONNECTOR ON THE PUMP AND THE AIRFRAME WIRING HAD SHORTED INTERNALLY. CONNECTOR AND BOOST PUMP WAS REPLACED.