Service difficulty report · Generator · Skrsky S76A

Difficulty date
September 16, 2003
Submitted
October 15, 2003
Operation
General aviation
Make and model
Skrsky S76A
Engine
Tmeca ARRIEL1S1
Part
Generator
Condition
Out Of Adjust
Location
Engine
Stage of operation
NR
How discovered
O
Nature of condition
Y, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING TRAINING, INFLIGHT ENGINE SHUTDOWN AND RESTART PROCEDURES WERE BEING DEMONSTRATED. WHEN START WAS ATTEMPTED THE THE OVERSPEED SYSTEM TRIPPED AND PREVENTED THE RESTART. TROUBLESHOOTING INDICATES THAT A OUTPUT VOLTAGE OF 28.55 VDC FROM THE OPERATING ENGINE GENERATOR WILL TRIP THE OVERSPEED SYSTEM AND PREVENT STARTING. ADJUSTMENT OF THE OUTPUT VOLTAGE TO 28.5 VDC HAS CORRECTED THIS PROBLEM.