Service difficulty report · Control Unit · Boeing 757256

Difficulty date
October 3, 2003
Submitted
November 3, 2003
Operation
General aviation
Make and model
Boeing 757256
Engine
Rroyce RB211535E437
Part
Control Unit
Part number
ETPU10002C
Part serial
BX32528
Condition
Will Not Test
Location
Tpu
Stage of operation
TX
How discovered
O
Nature of condition
X, J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LT ENGINE FLAMED OUT ON WHILE TAXIING IN. EICAS MSG 'LT ENG LP PUMP'. TROUBLESHOOT PER FIM 75-32-00 BITE CODE 90 ON THE TRANSIENT PRESSURE UNIT LED TO ITS REPLACEMENT. DURING ENGINE RUN N3 WAS NOTED TO BE ON LOWER END OF LIMIT PER MM71-00-00 FIG.517A. FUEL FLOW GOVERNOR REPLACED.