Service difficulty report · Generator · Bombdr DHC8400

Difficulty date
September 20, 2003
Submitted
January 5, 2004
Operation
General aviation
Make and model
Bombdr DHC8400
Engine
Pwc PW150A
Propeller
Rotol CR4086123F17
Part
Generator
Part number
11522184
Condition
Failed
Location
Nr 2 Ac
Stage of operation
TO
How discovered
O
Nature of condition
O
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found