Service difficulty report · Pump · Cndair CL6002B19

Difficulty date
March 22, 2004
Submitted
July 22, 2004
Operation
General aviation
Make and model
Cndair CL6002B19
Aircraft time
20,027 hours
Engine
Ge CF343A1
Part
Pump
Part number
848847
Condition
Contaminated
Location
Hyd Sys
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FAULT:AFTER TAKE-OFF MASTER WARNING AND GEAR DISAGREE MSG ON EICAS. ACTION: FOUND METAL CONTAMINATION IN HYD. SYST. NR 3, IN RETURN PRESS, CASE DRAIN FILTERS. ALL FILTERS REPLACED AND SYSTEMS FLUSHED IAW AMM 29-10-00-617-803. HYD PUMPS 3A, B REPL'D. NOSE GEAR STRUT SERVICED AND G/SWING C/OUT IAW AMM 32-20-00. ACFTSERV.