Service difficulty report · Control Unit · Bombdr BD7001A10

Difficulty date
September 28, 2004
Submitted
January 5, 2005
Operation
General aviation
Make and model
Bombdr BD7001A10
Engine
Rroyce BR700710A220
Part
Control Unit
Part number
763077J
Part serial
0224
Condition
Burned
Location
Slat/Flaps
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING ROUTINE MAINTENANCE, THE CREW REPORTED THAT THE NR 2 SFCU CIRCUIT BREAKER POPPED TWICE AND WERE RESET TWICE. THEY THEN SMELLED SMOKE COMING FROM THE AVIONICS BAY. THE SOURCE OF SMOKE WAS TRACED BACK TO THE SFCU. THE SFCU WAS REMOVED AND WAS FOUND TO HAVE TWO (2) HOLES BURNED THROUGH ON THE SIDE. THE BOX WAS REMOVED FROM THE RACK.