What was found
(CAN) CASEY HEATER BLOWER MOTOR CIRCUIT BREAKER TRIPPED TWICE DURING THE FIRST 2 HOURS OF USE AFTER MOTOR OVERHAUL. INSPECTION REVEALED THAT THE CASEY HEATER POWER WIRE BETWEEN THE CB SWITCH AND THE CAPACITOR WAS 16 GAUGE. THE CASEY INSTALLATION INSTRUCTIONS CALL FOR 10 GAUGE WIRE. REPLACED 16 GAUGE WIRE WITH 10 GAUGE WIRE. INSTALLED NEW 35 AMP CIRCUIT BREAKER DUE TO AGE. INSTALLED PANEL AMP METER BETWEEN COB AND BLOWER AND RAN FAN TO VERIFY AMP DRAW. AMP DRAW DETERMINED TO BE 43 AMPS AT START UP AND 23 AMPS CONTINUOUS. SYSTEM OPERATING NORMAL.