As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(CAN) UNABLE TO START NR 2 ENG. DUE FUEL VALVE LT AT PEDESTAL & EICAS MSG FOR 'R FUEL VALVE'. CHECKED 28VDC AT FUEL CUTOFF SW AND PWR AVAILABLE. REPLACED FUEL S/O VALVE SOLENOID, NO FIX. REPLACED HMU, NO FIX. REMOVED FUEL PUMP AND FOUND CONTAMINATED WITH METAL. MPN 9355M33P13 IN (STREAMER CAVITY).