Service difficulty report · Proximity Switch · Fokker F28MK0100

Difficulty date
November 21, 2004
Submitted
January 5, 2005
Operation
General aviation
Make and model
Fokker F28MK0100
Engine
Rroyce TAY65015
Part
Proximity Switch
Part number
864401
Condition
Faulty
Location
Stab
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AC DIVERTED, AFTER HAVING A HYDR STAB NR 1 FAULT IN FLIGHT (LOST FAULT ON LANDING). MAINT C/OUT A HYDR CONTROL STABILIZER OPS CHECK IAW AMM 27-42-01, NO FAULT FOUND. ON FOLLOWING FLIGHT, SAME MESSAGE REAPPEARED ON THE MSDS (MULTI FUNCTIONAL DISPLAY SYSTEM) AT THE TOP OF THE DESCENT. MAINT TESTED THE STAB SYSTEM IAW AMM 27-42-01. ALL INDICATIONS FOUND NORMAL. FUNCTIONAL TEST OF STICKING SWITCH WAS C/OUT IAW AMM 27-42-01-710-054-A03. NO FAULTS FOUND. ON NR 1 ENGINE START, HYDRAULIC STAB 1 FAULT OCCURRED. MAINT TROUBLESHOOTING CONFIRMED THE NR 1 STAB PROXIMITY SWITCH P/N OFF, 8-644-01, S/N OFF, 330- P/N ON, 8-644-01, S/N ON, A2231) AT FAULT AND WAS REPLACED AND TESTED IAW AMM 27-42-01.

More about the Fokker F.28 MK 0100