Service difficulty report · Proximity Sensor · Cndair CL6002B19

Difficulty date
December 16, 2004
Submitted
March 3, 2005
Operation
General aviation
Make and model
Cndair CL6002B19
Engine
Ge CF343A1
Part
Proximity Sensor
Part number
864808
Part serial
D1164
Condition
Malfunctioned
Location
Mlg
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found