What was found
DURING CLIMB, IDG NR 2 DROPPED OFF LINE. MAINTENANCE FOUND THE GENERATOR NR 2 CABLE AND TERMINAL BURNT IN JB1. THE TERMINAL ATTACHMENT HARDWARE WAS FOUND LOOSE ON THE TERMINAL BLOCK STUD INSIDE THE JB1. DAMAGED PARTS, ELECTRICAL HARNESS, 601R57640-1PE- PHENOLIC INSULATOR, 600-51428-3- BUS BAR,601R51427-3 - STUD, MS25080-4