What was found
(CAN) FOLLOWING TAKEOFF, THE LOW ENGINE OIL PRESSURE WARNING ANNUNCIATED FOLLOWED BY AN UNCOMMANDED REDUCTION IN POWER. FUEL CONTROL MANUAL OVERRIDE WAS ENGAGED AFTER WHICH FLAMES WERE EMITTED FROM THE EXHAUST AND THE ENGINE FLAMED OUT. SUBSEQUENT INSPECTION REVEALED NO OIL REMAINING IN THE ENGINE AND SEIZURE OF THE POWER SECTION. PWC WILL INVESTIGATE THIS EVENT AND WILL ADVISE OF ROOT CAUSE, ONCE ESTABLISHED.