What was found
(CAN) DURING A SCHEDULED DETAILED STRUCTURAL INSPECTION OF AIRCRAFT AT FRAME SPLICES AT STA 136.80 AND STR 15A, 5310/29C. CRACKING WAS FOUND ON FRAME SPLICES AND ADDITIONAL STRAPS AS PER MOD 8/0340, LT AND RT PROCEEDED WITH BOMBARDIERS RD-8-53-3541FOR PERM REPAIR TO FRAME SPLICES AND STRAPS. UPON REMOVAL OF LT FRAME SPLICE AN OTHER CRACK WAS DETECTED APPROXIMATELY ONE HALF INCH IN LENGTH, THUS SUBMITTED ADDITIONAL DAMAGE REPORT TO BOMBARDIER AND WAS ISSUED AN ADDITIONAL, RD 8-53-8673. REPAIRS WERE CARRIED OUT AND NO FURTHER INCIDENTS.