Service difficulty report · Diode · Beech 200BEECH

Difficulty date
September 1, 2005
Submitted
October 3, 2005
Operation
General aviation
Make and model
Beech 200BEECH
Aircraft time
15,348 hours
Engine
Pwa PT6A41
Part
Diode
Part number
IN4005
Condition
Burned
Location
Temp Control Box
Component
Temp Control · Barbercol
Component part number
HYLZ503361
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AIRCRAFT DEPARTED, 30 KM OUT, REPORTED SMOKE IN THE CABIN. THE SMOKE DISSIPATED AND THE FLIGHT LANDED. MAINTENANCE FOUND THE CABIN TEMP CONTROL HAD A BURND DIODE IN IT. THE CONTROLLER WAS REMOVED AND THE SYSTEM WAS DEFERRED IAW THE MEL. AIRCRAFT THEN CONTINUED OPERATING UNDER THE MEL AND RETURNED TO BASE THAT EVENING. OPEN DIODES IN THE CONNECTOR TO THE LT HEAT EXCHANGER BYPASS VALVE WERE REPLACED AS THE SUSPECT CAUSE OF THE DIODES OVERHEATING IN THE CABIN TEMP CONTROLLER. AIRCRAFT WAS RETURNED TO SERVICE AFTER CLEARING THE DMI.