Service difficulty report · Circuit Breaker

Difficulty date
January 3, 2006
Submitted
June 6, 2006
Operation
General aviation
Part
Circuit Breaker
Condition
Burned
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT HAD NR 1 AC GENERATOR INOPERATIVE (GOES OFFLINE AFTER 20 SECONDS). INITIALLY, THE GENERATOR HAD BEEN REPLACED, HOWEVER, THE DISCREPANCY REMAINED. SUBSEQUENTLY, CIRCUIT BREAKER, P/N 2TC2-5 FOUND WITH HOLE BURNT IN THE SIDE. FOR RECTIFICATION PURPOSES, CONTACTOR RELAY 2421-K1 REPLACED. RING CONNECTORS TO CB3 AND CB5 REPLACED, P/N HC-AJN022 (CONTACTOR RELAY), P/N 2TC2-5 (CB3) & (CB5).