What was found
(CAN) POWER SECTION WAS RECEIVED FROM THE OPERATOR FOR REPAIR DUE TO HIGH VIBRATION LEVELS. INSPECTION REVEALED THAT THE COMPRESSOR TURBINE BLADES HAD SUFFERED EXTENSIVE DAMAGE. 12 CT BLADES WERE FOUND DAMAGED TO VARYING DEGREES OF THE BLADE SURFACE MISSING. ANOTHER 12 BLADES EXHIBITED FATIGUE CRACKING EMANATING FROM THE TRAILING EDGE OF THE BLADE. (TC NR 20060306006)