What was found
MASS BALANCE ARM EXHIBITED LOOSENESS, AND WAS MOVING IN EXCESS OF 1/2 INCH AT THE END WHEN MOVED WITH MINIMAL HAND PRESSURE. AILERON DISASSEMBLED, FASTENERS REPLACED AND RETURNED TO SAFE AND FIT CONDITION IAW TYPE DESIGN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MASS BALANCE ARM EXHIBITED LOOSENESS, AND WAS MOVING IN EXCESS OF 1/2 INCH AT THE END WHEN MOVED WITH MINIMAL HAND PRESSURE. AILERON DISASSEMBLED, FASTENERS REPLACED AND RETURNED TO SAFE AND FIT CONDITION IAW TYPE DESIGN.