What was found
GUIDE PLATE SEPARATED FROM HORIZONTAL STAB FILLET, WAS FOUND LYING BETWEEN VERTICAL STABILIZER AND HORIZONTAL STABILIZER. UNIT HAD BEEN CRUSHED BETWEEN HORIZONTAL STAB AND VERTICAL STAB AS STAB WAS TRIMMED POTENTIAL THAT GUIDE PLATE COULD HAVE MOVED AFT AND JAMMED ELEVATOR LINKAGE. UNIT WAS REMOVED STRAIGHTENED AND REATTACHED TO HORIZONTAL STAB FILLET ASSEMBLY PER MANUFACTURERS INSTRUCTIONS "SRM SI-20-05, S0-10-04, HORIZONTAL STAB WAS TRIMMED THROUGHOUT ITS ENTIRE RANGE AND NO DISCREPANCIES FOUND.