Service difficulty report · Pump · Bombdr DHC8400

Difficulty date
July 14, 2006
Submitted
September 7, 2006
Operation
General aviation
Make and model
Bombdr DHC8400
Engine
Pwc PW150A
Propeller
Rotol CR4086123F17
Part
Pump
Part number
6617303
Condition
Split
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) NR1 EDP FAILED DURING FLIGHT CAUSING NR1 HYDRAULIC SYSTEM DEPLETION. EMERGENCY CHECKLIST PERFORMED. UNEVENTFUL LANDING AND A/C STOPPED ON RWY AND LATER TOWED TO PARKING POSITION. PUMP HOUSING FOUND SPLIT. EDP REPLACED. GROUND RUNS AND LEAK CHECK CARRIED SERVICEABLE. A/C HAS BEEN RTS. (TC NR 20060718001)