What was found
(CAN) NOSE GEAR GREEN LIGHT DID NOT ILLUMINATE WITH LANDING GEAR SELECTED DOWN. VISUALLY INSPECTED TO ENSURE NOSE GEAR WAS DOWN AND LOCKED THROUGH VIEWPORT AND CONFORMED NOSE GEAR WAS DOWN AND LOCKED. AS A PRECAUTIONARY ACTION NOSE GEAR LOCK SWITCH REMOVED AND REPLACED ALONG WITH CONNECTOR D298 IAW MM 32-61-71. FUNCTION CHECKED SERVICEABLE. NO FURTHER OCCURRENCE REPORTED. (TC NR 20061218013)