What was found
(CAN) DURING SCHEDULED LANDING GEAR ROUTINE INSPECTION, LANDING GEAR ACTUATOR GEARBOX MOUNTING BOLTS (3) FOUND MISSING AND REMAINING (1) BOLT FOUND SHEARED. EMERGENCY GEAR OPERATION ATTEMPTED TO RELOCATE GEAR. EMERGENCY OPERATION INHIBITED DUE TO IMPROPER GEARBOX ALIGNMENT. GEAR REPOSITIONED AND GEARBOX AND LANDING GEAR SYSTEM INSPECTED FOR CONDITION. NEW MOUNTING BOLTS INSTALLED AND GEAR SYSTEM NORMAL AND EMERGENCY TESTED SERVICEABLE. (TC NR 20070115015)