What was found
(CAN) DURING A REGULAR SCHEDULED MAINTENANCE B-CHECK, THE MAINTENANCE GUIDE CHECKLIST CALLED FOR A VISUAL INSPECTION IN ZONE 330/340 FUSELAGE TO WING AREA, BS 388-434. A SMALL 1 INCH CRACK WAS FOUND STEMMING FROM UNDERNEATH THE SHEAR PLATE AT BS 388. AFTER REMOVAL OF THE PRC, PAINT STRIPPING, AND COMPLETING A LIQUID DYE PENETRANT INSPECTION, (2) CRACKS AT STA 388 BETWEEN WL216 AND WL210 WERE IDENTIFIED. ONE CRACK WAS APPROXIMATELY 3.5 INCH AND THE OTHER APPROXIMATELY 0.5 INCH. PICTURES AND INFORMATION SENT TO THE MFG FOR DIRECTION TO COMPLETE THIS REPAIR. (TC NR 20070321012)