What was found
(CAN) DURING A AND B5 INSPECTION NR 7 SLAT ATTACH BRACKET UPPER MOUNT ON FRONT SPAR CRACKED. P/N TO BE DETERMINED FROM MFG ENGINEERING DRAWINGS. RDA ISSUED BY DECA ENGINEERING TO REPAIR. (TC NR 20070427006)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) DURING A AND B5 INSPECTION NR 7 SLAT ATTACH BRACKET UPPER MOUNT ON FRONT SPAR CRACKED. P/N TO BE DETERMINED FROM MFG ENGINEERING DRAWINGS. RDA ISSUED BY DECA ENGINEERING TO REPAIR. (TC NR 20070427006)