Service difficulty report · Inverter · Bombdr BD1001A10

Difficulty date
November 29, 2007
Submitted
January 21, 2008
Operation
General aviation
Make and model
Bombdr BD1001A10
Engine
Rroyce BR700710A220
System (JASC)
2422 · AC Inverter
Part
Inverter
Part number
GC53100043
Condition
Overheated
Part time
257 hours
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING MAINT AND AFTER THE AC HAD BEEN POWERED WITH EXTERNAL GROUND POWER FOR APPROX 4 HOURS, THE CREW NOTICED A BURNING SMELL AROUND THE AC. NO ABNORMAL INDICATIONS WERE DISPLAYED ON THE CREW ALERTING SYS (CAS) MESSAGE AND THE ELECTRICAL MGMT SYS CONTROL AND DISPLAY UNITS (EMSCDU). THE POWER WAS REMOVED FROM THE AC. THE INVESTIGATION INDICATES THAT THE INTEGRAL LIGHTING INVERTER A179 SHOWN SIGN OF INTERNAL OVERHEATING. THIS RESULTED IN DEPOSITING SOOT TO THE ADJACENT INTEGRAL LIGHTING POWER SUPPLY A176 AND WIRES. BOTH UNITS WERE REMOVED, REPLACE AND SENT TO THE VENDOR TO IDENTIFY THE ROOT CAUSE OF THE FAILURE. THE AC IS BACK IN SERVICE. (TC NR 20071130002)