Service difficulty report · Sensing Element · Cndair CL6002B19

Difficulty date
December 23, 2007
Submitted
January 21, 2008
Operation
General aviation
Make and model
Cndair CL6002B19
Aircraft time
12,875 hours, 10,857 cycles
Engine
Ge CF343B1
Part
Sensing Element
Part number
355924400
Condition
Chafed
Location
14th Stage Duct
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) RT 14TH STAGE DUCT MESSAGE DURING CLIMBOUT. FLIGHT RETURNED TO AIRFIELD. MAINTENANCE INSPECTION DISCOVERED 14TH STAGE COWL DUCT INSULATION BROKEN AND CHAFING ON SENSING LOOP. BOTH SENSING LOOP AND DUCT WERE REPLACED AND ENGINE RUN’S WERE C/O AND THE AC WAS CHECKED SERVICEABLE. (TC NR 20071227002)