Service difficulty report · Relay · Cndair CL6002B19

Difficulty date
December 24, 2007
Submitted
February 15, 2008
Operation
General aviation
Make and model
Cndair CL6002B19
Aircraft time
10,849 hours
Engine
Ge CF343A1
Part
Relay
Part number
VS643
Condition
Failed
Location
Electrical Pwr
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) UPON ARRIVAL, GROUND PWR APPLIED TO AC BUT SHUTOFF IMMEDIATELY. GROUND PWR RESTARTED AND AFTER ABOUT A MINUTE CREW NOTED NUMEROUS CIRCUIT BREAKERS POPPED, HEARD A LOUD BANG FROM THE NOSE SECTION AND A LIGHT SMELL OF SMOKE IN THE COCKPIT. CIRCUIT BREAKERS POPPED INCLUDED CENT TRU 1, NAV LIGHTS, TRU 1, TRU2, STCU, TRU SERVICE, SENSOR TOILET, CEILING LIGHTS, SIDEWALL LIGHTS AND STAB CHAN HSTCU. MAINT TROUBLESHOOTING, TRACED FAULT TO AN AC SERVICE BUS FAULT. PWR SENSE RELAY K5XD ( P/N VS-643) IN JB6 REPLACED (SHORTED WIRING ALSO REPAIRED). NUMEROUS OTHER PARTS REPLACED DUE TO DOWN LINE FAILURES. ( HSTCU P/N 7060-10, S/N 213.) LT AND RT WINDSHIELD HEAT CONTROLLERS P/N 601R59006-5, S/N’S 5131 & 3475(SOME BURNED CONNECTOR PINS P/N M83723-75R20256 ALSO REPLACED). (LT AND RT BOARD ASSY COMPONENT FILTER P/N’S 601R5138-11/01 AND /02. - FUSE P/N FM01A125V1-1-2A FOR PILOT`S SIDE CONSOLE INTEGRAL LIGHTING POWER SUPPLY/DIMMING UNIT. (RT IB NAV LIGHT P/N 9203.) UPPER TAIL NAV LIGHT P/N 1683. (STAB MOTOR CONTROL UNIT P/N 7062, S/N 367. - NR 2 LOGO LIGHT P/N 4626. (TC NR 20080105001)