Service difficulty report · Sensor · Dhav DHC8102

Difficulty date
January 10, 2008
Submitted
January 21, 2008
Operation
General aviation
Make and model
Dhav DHC8102
Aircraft time
11,327 hours
Engine
Pwa PW120A
Propeller
Hamstd 14SF7
Part
Sensor
Condition
Open
Location
Nr 2 A/C Gen
Component
Generator · Lucas · 31708001A
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) HAD A FAILURE OF THE NR 2 AC GEN THE PREVIOUS WEEK, THE AC GEN WAS REPLACED WITH AN O/H UNIT. THE AC TOOKOFF AND AT 7000 FEET HAD A NR 2 AC GENERATOR FAIL, THE AC RETURNED TO THE AIRPORT. INVESTIGATION WAS C/O AND FOUND THAT THE SPEED SENSOR WAS OPEN. THE UNIT SENT BACK TO THE SHOP REPLACED THE SPEED SENSOR, UNIT REINSTALLED ON THE A/C AND FOUND SERVICEABLE. A/C DEPARTED ON JAN 14-2008 AND NO OTHER REPORT REPORTED. (TC NR 20080114003)