What was found
(CAN) FLOORBEAM AT BS 98605, RBL 27, WL 207.5 CORRODED UNDERSIDE UNDER CLIP NUT. REPAIRED WITH REPAIR PART IAW CUSTOMER EA AND SRM. (TC NR 20080325010)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) FLOORBEAM AT BS 98605, RBL 27, WL 207.5 CORRODED UNDERSIDE UNDER CLIP NUT. REPAIRED WITH REPAIR PART IAW CUSTOMER EA AND SRM. (TC NR 20080325010)