What was found
(CAN) FOLLOWING THE COMPLETION OF AD CF2008-09, WHILE PERFORMING A FUNCTION CHECK OF THE AIR DRIVEN GENERATOR, 2 OF THE 3 MAIN FEED WIRES WERE FOUND BROKEN AFT OF THE CONNECTOR P1XC. CLOSER INSPECTION OF THE WIRES REVEALED PITTING CORROSION AND BREAK IN SEVERAL STRANDS OF THE WIRES. ALL 3 WIRES WERE REPLACED AS AN ASSEMBLY P/N M27500-8SP3U00.