Service difficulty report · Alternator · Diamon DA40

Difficulty date
September 18, 2008
Submitted
November 3, 2008
Operation
General aviation
Make and model
Diamon DA40
Part
Alternator
Part number
ALU8521LS
Condition
Intermittent
Part time
6 hours
Stage of operation
CL
How discovered
O
Nature of condition
H, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) INSUFFICIENT CLEARANCE BETWEEN THE HEAD OF THE FIELD TERMINAL STUD AND HSG. BRUSH HOLDER ASSY WHEN FLEXED INWARD, CAUSES THE HSG AND HEAD OF THE STUD TO TOUCH. IF YOU REMOVED THE BRUSH HOLDER ASSY YOU WILL NOTICE THAT THE RING TERMINAL THAT IS CRIMPED TO THE BRUSH LEAD IS SLIGHTLY LARGER THAN THE HEAD OF THE TERMINAL BOLT. IT IS ACTUALLY THE RING TERMINAL THAT TOUCHES THE HSG. THIS TRIPS THE VOLTAGE REGULATOR OFF LINE. THE ALTERNATOR SWITCH NEEDS TO BE CYCLED TO RESET THE REGULATOR.