What was found
(CAN) UPON REMOVAL OF LT GEAR ACTUATOR DUE TO HYDR BYPASS, CONICAL SPACER, P/N 2441007-1, ITEM NR 32 IN IPC 32-32-20, WAS FOUND CRACKED. RT ACTUATOR REMOVED, SPACER VISUALLY INSPECTED. NO CRACK INDICATIONS. BOTH ACTUATOR PILLARS REMOVED, CLEANED AND MAGNETIC PARTICLE INSPECTED IAW NDT MANUAL. NO DEFECTS NOTED. SURROUNDING AREA VISUALLY INSPECTED, NO DEFECTS NOTED. ACTUATORS INSTALLED WITH NEW SPACERS ON BOTH SIDES IAW ACFT MM. F/C OF GEAR C/O SERVICEABLE.