Service difficulty report · Circuit Breaker · Dhav DHC6300

Difficulty date
December 18, 2008
Submitted
February 2, 2009
Operation
General aviation
Make and model
Dhav DHC6300
Aircraft time
18,653 hours
Engine
Pwa PT6A34
Part
Circuit Breaker
Part number
7271835
Condition
Unserviceable
Location
Cockpit
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) THE FLIGHT CREW REPORTED THE 35 AMP HYDRAULIC PUMP CIRCUIT BREAKER POPPED. THEY ELECTED TO RETURN TO BASE AND USED HYDRAULIC HAND PUMP FOR BRAKE OPS. MX TROUBLESHOT THE SYSTEM, REPLACED 35 AMP CIRCUIT BREAKER, GROUND TESTED THE SYSTEM, AND RETURNED THE ACFT TO SERVICE.